Ac Power Cord; Trunk/Extension Cabling; General; Precautions For Cabling - NEC SL1100 Hardware Manual

Communication system
Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 1.0
Ground Requirement
Feeding Voltage
AC Input I
KWh
BTU (KWh x 3413)

1.5.3 AC Power Cord

The AC power switch and AC power inlet are located at the left side of each KSU. The AC power cord
is connected to the AC inlet and the commercial AC power socket.
Do not plug-in AC power cord if the KSU Cover is removed.
Before connecting the AC power cord, make sure:
• The power switch at the left side of each KSU is turned OFF.
• The power switch at the commercial AC power socket is turned OFF.
• The AC plug fits the commercial AC power socket. The plug adapter is neces-
sary if it does not fit.
"B" type
To Commercial
AC Power Socket
• Each KSU must have its own commercial AC power socket.
• DO NOT POWER ON until all KSU installation has been completed.

1.6 Trunk/Extension Cabling

1.6.1 General

The system provides RJ61 modular jacks for analog trunk and analog/digital extension connections.

1.6.2 Precautions for Cabling

• Do not wire the cable with an AC cable, computer, etc.
Hardware Manual
110VAC
120VAC
Main KSU =
Main KSU =
1.16 A
1.08 A
3 KSU Total =
3 KSU Total =
3.48 A
3.24 A
Main KSU =
Main KSU =
0.128 KWh
0.130 KWh
3 KSU Total
3 KSU Total
=0.384 KWh
=0.390 KWh
Main KSU =
Main KSU =
437 BTU
444 BTU
3 KSU Total
3 KSU Total
=1311 BTU
=1332 BTU
Connect
AC Power Cord

Figure 2-20 AC Power Cord

220VAC
230VAC
No.14 AWG Copper Wire
SLT: 20 mA/ -27 V
Main KSU =
Main KSU =
0.70 A
0.67 A
3 KSU Total =
3 KSU Total =
2.10 A
2.01 A
Main KSU =
Main KSU =
0.154 KWh
0.154 KWh
3 KSU Total
3 KSU Total
=0.462 KWh
=0.462 KWh
Main KSU =
Main KSU =
526 BTU
526 BTU
3 KSU Total
3 KSU Total
=1578 BTU
=1578 BTU
SL1100
240VAC
Main KSU =
0.65 A
3 KSU Total =
1.95 A
Main KSU =
0.156 KWh
3 KSU Total
=0.468 KWh
Main KSU =
532 BTU
3 KSU Total
=1596 BTU
KSU
2-13