Table 4-1 Status Leds; Figure 4-17 Inserting The Cf Card; Figure 4-18 Load Button (S1) Location - NEC SL1100 Hardware Manual

Communication system
Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
CF card
5. Push in and hold the LOAD button (S1 on the CPU card).
Sub-Cover
Tab
6. Turn the system power on.
7. Continue holding the LOAD button (S1) for approximately 10 seconds or until Status LED (D5)
starts flashing red.
8. Release the LOAD button (S1).
9. Wait until the Status LEDs (D2 to D5) on the CPU card has the following indications (approxi-
mately two minutes).
LED No.
D2
D3
D4
D5
10. Turn the power off and remove the CF card from the CF slot on VMDB.
4-10

Figure 4-17 Inserting the CF card

Tab

Figure 4-18 LOAD Button (S1) Location

Table 4-1 Status LEDs

Indication
Flashing Red
Flashing Red
Flashing Red
Off
CPU card
CF Slot (CN2)
VMDB
D2 (Red)
D1 (Blue)
D3 (Red)
D4 (Red)
D5 (Red)
CPU card
S1
< Front view >
Remarks
ISSUE 1.0
Maintenance