Ac Power Requirement; Ac Power Cord; Table 2-5 Power Requirement - NEC SL1100 Hardware Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
2.
Insert a grounding wire (user supplied).
3.
Tighten the screw.
4.
Connect the grounding wire to earth ground.
Proper grounding is very important to protect the system from external
noise and to reduce the risk of electrocution in the event of a lightning
strike.

1.5.2 AC Power Requirement

A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Power Requirement
Power Consumption
Input Voltage (Rated Voltage)
Frequency
Phase and Wire
Ground Requirement
Feeding Voltage
AC Input I
KWh
BTU (KWh x 3413)

1.5.3 AC Power Cord

The AC power switch and AC power inlet are located at the left side of each KSU. The AC power cord
is connected to the AC inlet and the commercial AC power socket.
Do not plug-in AC power cord if the KSU Cover is removed.
Before connecting the AC power cord, make sure:
• The power switch at the left side of each KSU is turned OFF.
• The power switch at the commercial AC power socket is turned OFF.
2-14

Table 2-5 Power Requirement

110VAC
120VAC
110 VAC@15 A 120 VAC@15 A 220 VAC@15 A 230 VAC@15 A 240 VAC@15
Main KSU =
Main KSU =
128 VA
130 VA
3 KSU Total =
3 KSU Total =
384 VA
390 VA
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
47 Hz - 63 Hz (Rated Frequency: 50/60 Hz)
Single Phase, 2 Line + PE Type
Main KSU =
Main KSU =
1.16 A
1.08 A
3 KSU Total =
3 KSU Total =
3.48 A
3.24 A
Main KSU =
Main KSU =
0.128 KWh
0.130 KWh
3 KSU Total
3 KSU Total
=0.384 KWh
=0.390 KWh
Main KSU =
Main KSU =
437 BTU
444 BTU
3 KSU Total
3 KSU Total
=1311 BTU
=1332 BTU
220VAC
230VAC
Main KSU =
Main KSU =
154 VA
154 VA
3 KSU Total =
3 KSU Total =
462 VA
462 VA
No.14 AWG Copper Wire
SLT: 20 mA/ -27 V
Main KSU =
Main KSU =
0.70 A
0.67 A
3 KSU Total =
3 KSU Total =
2.10 A
2.01 A
Main KSU =
Main KSU =
0.154 KWh
0.154 KWh
3 KSU Total
3 KSU Total
=0.462 KWh
=0.462 KWh
Main KSU =
Main KSU =
526 BTU
526 BTU
3 KSU Total
3 KSU Total
=1578 BTU
=1578 BTU
ISSUE 5.0
240VAC
A
Main KSU =
156 VA
3KSU Total =
468 VA
Main KSU =
0.65 A
3 KSU Total =
1.95 A
Main KSU =
0.156 KWh
3 KSU Total
=0.468 KWh
Main KSU =
532 BTU
3 KSU Total
=1596 BTU