Washer Will Not Start - No Door Lock - ALLIANCE HWF561*E1102 Service

Commercial front control washers
Table of Contents

Advertisement

Section 3 Troubleshooting (MDC Models)
21. WASHER WILL NOT START – NO DOOR LOCK
Washer will not
start. Vend
satisfied.
(1)
Is there 120 Volt
AC across "H4-5" and
"H6-5" on the control
board?
No
(2)
Is there voltage
to the blu/blk input wire
to the door switch on the
lock assembly?
No
(3)
Is there voltage
at the input blk wire coming
into the secondary
door switch?
No
Correct wiring to
the secondary
door switch.
48
Washer Will Not Start. No Door Lock.
Replace the Door
Lock Assembly.
Yes
Is there 120 Volt
Yes
AC across "H4-4" to "H6-5" on
the control board?
Yes
Replace the Door
Lock Assembly.
Replace the
Yes
secondary door
switch assembly.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(4)
No
AC across "H6-1" and "H6-5"
on the control board?
No
(5)
Is there 120 Volt
Yes
Replace the
Control Board.
FLW300S
800168

Hide quick links:

Advertisement

Table of Contents
loading