38. CONTROL PANEL

IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch washer while it is plugged in before handling
control to dissipate any charge.
STEP 1
.
Unlock control panel.
800168
Section 5
Service Procedures
Move top of control panel away
from control cabinet and lift up.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
a. Unlock control panel. Refer to Figure 17, Step
1.
b. Pull top of control panel away from control
cabinet far enough to allow lifting control panel
up and off the rail support of the control
cabinet. Refer to Figure 17, Step 2.
c. Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 17, Step 3.
d. While supporting control panel, disconnect all
wires and harness connectors from electronic
control and indicator light.
NOTE: DO NOT pull on wires. Instead, hold board
near appropriate disconnect block and unplug by
pulling on disconnect block.
e. Remove ground clip holding ground wire to
control panel.
NOTE: Refer to wiring diagram when reconnecting
wires.
STEP 2
.
Figure 17
STEP 3.
Remove control panel
out of control cabinet.
H099SE3A
W003
83