Washer Will Not Pump - ALLIANCE HWF561*E1102 Service

Commercial front control washers
Table of Contents

Advertisement

Section 3 Troubleshooting (EDC Models)

13. WASHER WILL NOT PUMP

Check for a kink or blockage
Change inoperative pump.
32
Washer will not pump
(1) "AC"
Is there voltage at
"H5-3" to "FS-2" on
EDC control
board?
Yes
(2) "AC"
Is there voltage across
wires going to
pump?
Yes
in drain hose.
Check for blockage in
pump's button trap.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Note:
Make sure washer cycle is in
drain/spin.
No
Change inoperative EDC
control board.
No
Correct wiring between
pump and EDC control
Still will not pump.
Still will not pump.
board.