Coins Ignored When Entered - ALLIANCE HWF561*E1102 Service

Commercial front control washers
Table of Contents

Advertisement

Section 3 Troubleshooting (MDC Models)

19. COINS IGNORED WHEN ENTERED

Start Coin Drop Diagnostic Test. Refer
to programming manual.
Start Production Test Cycle.
Does the count on
the display increment
properly after entering
coins?
No
Is "H7" connector
properly seated on the
control board?
No
Properly reseat
connection and
conduct diagnostic
test again.
44
Coins Ignored When Entered.
Yes
Reset control to
ready mode.
From the coin drop, is
Yes
the 3-pin connector
properly plugged in?
Properly reseat
connection and
conduct diagnostic
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Yes
No
Replace electronic
test again.
Are the wires exiting the
coin drop optical sensor
cracked or broken?
No
control.
Yes
Replace the
coin drop.