ALLIANCE HWF561*E1102 Service page 120

Commercial front control washers
Table of Contents

Advertisement

f. Install pulley bolt tightening fixture between
the flat washer and the pulley. Refer to
Figure 44.
g. Tighten left hand thread screw until washer is
against pulley bolt tightening fixture.
h. Loosen screw about one half turn to free
fixture.
i. Remove pulley bolt tightening fixture.
j. From front of washer, pull inner basket forward
as far as possible. Flat washer should be against
pulley.
k. Push inner basket back into outer tub as far as
possible.
l. Tighten left hand thread screw. Be careful not
to push the trunnion shaft forward while
tightening the screw.
NOTE: Torque new left hand thread screw to 240
minimum to 260 maximum inch pounds (27.5 to
29.7 Nm).
800168
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 5 Service Procedures
118