Cannot Perform Infrared Communication - ALLIANCE HWF561*E1102 Service

Commercial front control washers
Table of Contents

Advertisement

Section 3 Troubleshooting (EDC Models)

6. CANNOT PERFORM INFRARED COMMUNICATION

Attempt to communicate with
electronic control from
Micro-wand.
Is there any
acknowledgement
of any kind from
electronic control?
Yes
Does electronic
control display
"E:OF" or "-C-"?
"E:OF"
Check the following:
- (IR) disabled by manual
program.
- Is (IR) on control covered
or blocked?
- If needed, change electronic
control board.
20
Aim Micro-wand
No
closer and try
"-C-"
Communication sequence
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
again.
checks out.
Is there any control
response?
Yes
Check the following:
- Low battery on Micro-wand.
- Is (IR) on control covered
or blocked?
- Is (IR) cap properly attached
to Micro-wand?
- If needed, replace electronic
control board.
No
H130S