Electrical Installation
Non-UL compliance fuses
Frequency
converter
200-240 V - T2
1K1-1K5
2K2
3K0
3K7
5K5
7K5
11K
15K
18K5
22K
30K
37K
45K
380-480 V - T4
1K1-1K5
2K2-3K0
4K0-5K5
7K5
11K-15K
18K
22K
30K
37K
45K
55K
75K
90K
1) Max. fuses - see national/international regulations for selecting an applicable fuse size.
Table 4.3: Non-UL fuses 200 V to 480 V
If UL/cUL is not to be complied with, we recommend using the
following fuses, which will ensure compliance with EN50178:
Frequency Converter
P110 - P250
P315 - P450
Table 4.4: Compliance with EN50178
®
VLT
HVAC Drive Operating Instructions
Max. fuse size
1
16A
1
25A
1
25A
1
35A
1
50A
1
63A
1
63A
1
80A
1
125A
1
125A
1
160A
1
200A
1
250A
1
10A
1
16A
1
25A
1
35A
1
63A
1
63A
1
63A
1
80A
1
100A
1
125A
1
160A
1
250A
1
250A
Voltage
380 - 480 V
380 - 480 V
®
MG.11.AD.02 - VLT
is a registered Danfoss trademark
Voltage
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type gG
200-240 V
type aR
200-240 V
type aR
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type gG
380-500 V
type aR
380-500 V
type aR
Type
type gG
type gR
Type
4
4
23

Hide quick links: