Power Supply, Management Board, and Spine Board Indicator Status
at Power ON
It can take up to 5 minutes to boot up the system. Turn off the system if any LEDs
remain red for more than 5 minutes.
As the power is turned on, you should observe the following conditions for normal operation:
Step 1.
Power Supply Unit(s) AC OK and DC OK indicators are ON and FAIL indicators are
OFF.
Step 2.
There is a green Status LED per spine board, per leaf board, and per management
module that indicates power supplies are good.
Step 3.
Spine Board indicators will display status of internal links to the installed leaf boards.
All PHY links to existing leaf Boards should be ON.
Step 4.
Check the Spine LEDs and make sure they coincide with Figure 26.
Step 5.
Check the Spine LEDs and make sure they coincide with Figure 27.

Figure 27: Management Module Status Indications for Normal Operation

IB
STATUS
34

Figure 26: Spine Side Panel Display Status Indications

STATUS
PSU
STATUS
I2C
CONSOLE
MGT
SPINE
LEAF
MNG 1
FANS
FANS
STATUS
RST
PSU
S.FANS
L.FANS
Chassis Power Up
MNG 2
STATUS
MASTER
MGT MAC:
00:02:C9:11:34:8A