FreedomHF_IC_01-Installation.fm Page 28 Monday, December 24, 2007 9:47 AM

Step 7: Mounting the Display Panel

The communications cable supplied with the display panel is 25 feet (7.62
meters) long. If you want to replace the cable with one that is shorter, use
a high quality, 6-wire telephone extension cable.
Flush mounting the panel on a wall, bulkhead, or panel requires an
opening that is approximately 3.25 × 1.25 inches (8.25 × 3.18 cm). About
1.5 inches (3.81 cm) of free space is required within the wall to
accommodate the depth of the panel. Be sure there is no wiring or other
obstructions within the wall before you make an opening.
To mount the display panel:
1. Choose a location that is dry, out of direct sunlight, free from
2. Tape the mounting template (in the
3. Pilot-drill the mounting holes and cut out the hole in which the panel
4. Route the communications cable(s) inside the wall and through the
5. Insert one of the cable's connectors in either jack on the bottom of the
6. Place the panel in the opening and secure it with appropriate
7. Route the communications cable to the
Important:
with the AC and DC wires. In situations where the cable must cross with the AC
and DC wires, make sure they cross at a 90° angle to each other.
1–28
corrosive or explosive fumes, and otherwise appropriate for mounting
an electronic device.
mounting surface and mark the locations of the mounting holes and
the area to be cut away.
will be inserted.
opening.
panel.
fasteners.
connector in the jack located near the battery select dip switch.
Do not route the communications cable in parallel and in conduit