Display Panel

1
3
FREEDOM HF
STATUS
Utility
Input Voltage (V)
4
Select
Input Current (A)
Battery
Output Power (kW)
Fault
Figure 9 Display Panel (All Models)
Item
1
Inverter Power button is the main unit switch that turns the
Freedom HF's inverter function ON or OFF.
2
Three-digit LED display screen shows status information and
fault codes.
3
Status LED indicates the mode of operation with a three-color LED.
4
Select button changes status information displayed on the display
screen.
IMPORTANT: See Display Panel Operation on page 29 for detailed information on operating the panel's
buttons
975-0390-01-01
2
Description

Remote and Power Module Panel

1
a
b
Figure 10 Remote and Power Module Panel (Freedom HF 1055
EMS,1800 EMS)
Item
1
Remote jack is used for connecting the Display panel that ships with
the Freedom HF 1055 EMS and 1800 EMS. Each shipment comes
with a 25-foot communications cable as well.
2
Power module has one fuse and three contacts for wires that
connect to:
a. an auxiliary 12-volt DC OUT terminal,
b. an Ignition Control terminal, and
c. a Disable terminal.
NOTE: The Ignition Control and Disable terminals are connected by a jumper wire that acts to
disable ignition control. Removing the jumper wire will enable ignition control.
For instructions on how to enable or disable Ignition Control, see
the Installation Guide.