Step 5: Connecting AC Output to an Existing AC Circuit

975-0395-01-01
WARNING: Shock, fire, and energy hazards
Make sure wiring is disconnected from all electrical sources before handling. All
wiring must be done in accordance with applicable local and national electrical
wiring codes.
WARNING: Shock hazard and equipment damage
Do not connect any AC source (such as a generator or utility power) to the
AC wiring output of the
Freedom
The
Freedom HF
will not operate if its output is connected to AC voltage from
another source, and potentially hazardous or damaging conditions may occur.
These conditions can occur even if the inverter is off.
Do not connect the
Freedom HF
high-power consumption loads.
The
Freedom HF
will not operate electric heaters, air conditioners, stoves,
and other electrical appliances that consume more than 1000 watts
(Freedom HF
1000) or 1800 watts
A Xantrex-tested and approved GFCI must be connected to the
HF
AC output, and on every receptacle connected to the AC hard wired
installation. Other types may fail to operate properly when connected to
the
Freedom
HF. Although you can reuse the factory-installed GFCI,
Xantrex has also tested and approved the following GFCIs for use with
the
Freedom
HF:
Make
Model
Hubbell
GFR5252
Leviton
6598
8598
For more information about GFCIs, see the application note "Using GFCI
Receptacles on Xantrex Inverters and Inverter/Chargers" in the Document
Library at www.xantrex.com.
This guide for use by qualified installers only
Basic Installation Procedures
HF.
to an AC branch circuit that has
(Freedom HF
1800).
Freedom
1–19