AC input
ground screw
AC knockout
Figure 1-5
Freedom HF
975-0395-01-01
5. Remove the left-hand side AC wiring knockout from the front panel
of the unit (see
Figure 1-5 on page
6. Install one of the supplied strain-relief clamps in the AC knockout.
7. Locate the terminal block.
The two input terminals are labeled as follows:
•
AC Input (L)
•
AC Input (N)
A separate screw is provided to connect the AC input ground (see
Figure 1-5 on page
1–17).
S TATUS
U til i t y
Inpu t Voltag e ( V )
S el e c t
B a tt e r y
Inpu t C u rre n t (A)
F ault
Outpu t P o w e r ( W )
AC Wiring Compartment
8. Strip about 2 inches (50 mm) from the jacket of the AC input cable.
The AC input cable may be either solid or stranded (as required), but
must have three conductors and be sized as in
(The AC terminal block accepts wire sizes up to No. 10 AWG.)
9. Strip approximately 3/8 inch (10 mm) from the insulation of each
conductor.
10. Run the AC cable through the right-hand side strain-relief clamp and
into the wiring compartment.
11. Fasten the Ground wire to the grounding screw.
12. Using the 1/8 inch slot screwdriver, loosen the wire attachment
screws on the terminals.
CAUTION: Reverse polarity
Improper connections (connecting a line conductor to a neutral conductor, for
example) will cause the
Freedom HF
damage the inverter. Damage caused by a reverse polarity connection is not
covered by your warranty.
This guide for use by qualified installers only
Basic Installation Procedures
1–17).
AC output
ground screw
FREEDOM HF 1000
AC knockout
Table 1-4 on page 1–16
to malfunction and may permanently
.
1–17