FreedomHF_IC_A-Specifications.fm Page 4 Monday, December 24, 2007 9:48 AM
Environmental Specifications
Ambient Temperature:
Operating Temperature Range
Storage Temperature Range
Humidity: Operation/Storage
System Specifications
Transfer relay rating
Transfer time
Transfer on bad voltage
Cooling
Physical Specifications
Unit Dimensions and Weight
Length
Width
Height
Weight
Regulatory Approvals
ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield
with product number 808-9531 required).
A–4
0–40 ºC
-20–60 ºC, with output derated above 25 °C
-40–70 ºC
5–95% RH, non-condensing
30A, 2.0hp
<30ms
90–100V for low AC and
130–140 for high AC
Fan, activated by any of the following:
•
•
Freedom HF 1000
15.5" (393mm)
9.5" (241mm)
4.2" (106mm)
10 lbs (4.5 kg)
This guide for use by qualified installers only
High internal temperature
High AC output power
Freedom HF 1800
18.0" (457mm)
9.5" (241mm)
4.2" (106mm)
12.8 lbs (5.8 kg)
975-0395-01-01