Setting Battery Types on the Main Unit

You can attach different types of lead-acid batteries to the
Before installing batteries make sure that you configure the unit to
optimize the charging process.
WARNING: Fire hazard
Incorrectly setting the battery type can lead to battery damage and a risk of fire.
The settings can be changed by adjusting the dip switches found on the
main unit behind the display panel.
Battery
Type
Fixed
Flooded
GEL
AGM
To adjust the battery type setting:
By default the battery type is set to Flooded (OFF|ON) .
1. Detach the Display Panel to expose the Dip Switches.
2. Use the tip of your fingernail or a small screw driver with a flat tip to

Figure 2-1 Dip Switches (Default Settings Shown)

2–2
Dip Switch Setting
Switch 1|Switch 2
OFF|OFF
OFF|ON (default)
ON|OFF
ON|ON
adjust the switches.
OFF
Switch 1 | Switch 2
This guide for use by qualified installers only
Freedom
Bulk/Absorption
Float
13.5
13.5
14.4
13.5
14.2
13.8
14.3
13.4
ON
975-0395-01-01
HF.

Hide quick links: