Removal/installation routines
Ê Attach the telescopic rail with no fastener (HL) to the rack on the right-hand
support uprights using two M5 screws.
Note that the guide nubs of the telescopic rail next to the spring nuts must
engage in the holes in the support uprights.
Ê Mount the DataCenter rack cable management (articulated cable guide) as
described in the Service Manual of the DataCenter rack (see module
"System components", article "DataCenter rack", section "Cable
management").
Ê Mount the server (see
Ê Route the cables with the server inserted, as described in the Service
Manual for the DataCenter rack (see module "System components", article
"DataCenter rack", section "Routing cables").
Ê Place the cage nuts for fastening the front panel in the corresponding holes
of the front support uprights at the marked points and fasten the server using
four knurled screws (see also figure on
Mounting in the Classic rack
For mounting the server in the Classic (19-inch) rack, you need the following
parts from the rack mounting kit S26361-F1331-L7:
– Two telescopic rails (assembled)
– Protective sheath for Fibre Channel fiber-optic cable
Ê See the assembly instructions in the technical manual for the Classic (19-
inch) rack.
Ê Using the mounting aid (stencil), mark the position of the attachment points
for the telescopic rails and for the server (front panel) on the support uprights
(four height units).
Make sure you read the information on the mounting aid.
Ê Place the spring nuts for fastening the telescopic rails in the relevant groove
of the support uprights at the attachment points marked.
Ê If necessary, adjust the position of the nuts in the groove until they lock into
the correct position.
U41057-J16-Z146-1-76
Installing/removing the rack model
page
02-TX600-185).
page
October 2003
02-TX600-188).
02
TX600
179