Brother DCP375CW Service Manual page 513

Injet dcp/mfc
Hide thumbs Also See for DCP375CW:
Table of Contents

Advertisement

Selector
No.
Prevention against line
1
disconnection during ICM
recording
|
(Percentage of guard tone response
3
time relative to end-of-call tone
ON time)
Trimming of R key signal issued
from cordless handset--For
4
connection to base unit with PBX
OFF (Not used.)
Call transfer to cordless handset
from telephone(s) connected in
5
parallel with the machine (base
unit) (Not used.)
Extension of the "No. of CNG
cycles to be detected" (which
allows two cycles to be added to
6
the cycles specified by selectors 6
and 7 on WSW26 and selectors 4
and 5 on WSW34)
7
No. of busy tone detection cycles
8
Note: Selectors 1 through 3 are applicable to models equipped with TAD.
Note: Selector 4 is applicable to European models with a cordless handset.
Note: Selector 5 is applicable to U.S.A. models with a cordless handset.
• Selectors 1 through 3: Prevention against line disconnection during ICM recording (Percentage
If the machine misdetects an ICM tone as an end-of-call tone, it disconnects the line even
during recording of the ICM. If it happens, change the percentage of the guard tone
response time relative to the end-of-call tone ON time with these selectors.
If the percentage of the actual guard tone response time is more than the setting made by
these selectors, the machine interprets it as no detection of end-of-call tone, continuing
recording the ICM.
WSW58
(Function setting 23)
Function
of guard tone response time relative to end-of-call tone ON time)
App. 4-60
Setting and Specifications
No. 1 2 3
0 0 0
: Disable
0 0 1
: 10%
0 1 0
: 20%
0 1 1
: 30% (default)
1 0 0
: 40%
1 0 1
: 50%
1 1 0
: 60%
1 1 1
: 70%
0: Disable
(default)
0: Enable
(default)
0: No
No. 7 8
0 0 :
-1 cycle
0 1 :
+0 cycles (default)
1 0 :
+1 cycle
1 1 :
+2 cycles
1: Enable
1: Disable
1: +2 cycles
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents