Assembling Notes:
• Before mounting the MJ shield, route the main-MJ (LINE) and (EXT) harnesses*
through the cable guide provided on the MJ PCB insulator*. (See the previous page.)
• Route the power cord through the PS insulator 200 V (see below) and the cable guides
provided on the AC cord holder (see
into the cutout provided in the lower MJ/PS shield as shown below.
• When mounting the power supply shield on the lower MJ/PS shield, insert two shield
supports of the power supply shield into the two square holes provided in the lower MJ/
PS shield. Make sure that the lock of the lower MJ/PS shield (as shown on the next page)
fits in the slit provided in the top of power supply shield. (See the previous page.)
Main-MJ (EXT)
harness (black)*
Main-MJ (LINE)
harness (yellow)*
PS insulator 200V
AC cord holder
Routing of power cord
page
6-57). Fit the corner of the PS PCB insulator
PS insulator 200V
Power supply PCB
Lower MJ/PS shield
Fit the corner of the PS PCB insulator
into the cutout provided in the lower
MJ/PS shield.
6-56
* For MFC only
Power supply PCB
Lower MJ/PS shield
Power supply harness