Selector
No.
1
Maximum OGM recording time
(Not used.)
2
Time length from CML ON to start
3
of pseudo ring backtone
4
transmission
Attenuator for playback of ICM/
5
OGM to the line
|
(Selectable from the range of
0-15 dB)
8
(Not used.)
• Selectors 1 and 2: Maximum OGM recording time (Not used.)
These selectors specify the allowable maximum recording time for an OGM.
• Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors specify the length of time from CML-ON up to the start of pseudo ring
backtone transmission.
In models with an OGM facility, the settings made by these selectors also apply to the
length of time from CML-ON up to the start of OGM transmission.
• Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line (Not used.)
Setting two or more selectors to "1" produces addition of attenuation assigned to each
selector.
This setting is not limited by selector 8 on WSW23.
WSW24
(TAD setting 2)
Function
App. 4-29
Setting and Specifications
No. 1 2
0 0 :
15 sec.
0 1 :
20 sec.
1 0 :
30 sec.
1 1 :
50 sec.
No. 3 4
0 0 :
4 sec.
0 1 :
3 sec.
1 0 :
2 sec.
1 1 :
1 sec.
No. 5 6 7 8
0 0 0 0 :
0 0 0 1 :
0 0 1 0 :
|
1 1 1 1 :
0 dB
1 dB
2 dB
|
15 dB
sec.: second(s)