9.4.19 Travel Check of the Head/Carriage Unit and Initial Setup Mode
(Function code 63)
Function
This procedure moves the head/carriage unit to the center of its travel (Function code 63 + *).
NOTE: In models with touch panel, press the Black Start (Mono Start) key, press the Scan
and Copy keys simultaneously, and then press the * key.
It can also enable or disable the initial setup mode when the power is applied at the next time
(Function code 63 + 1 or Function code 63 +3).
Operating Procedure
(1) Press the 6 and 3 keys in this order in the initial stage of the maintenance mode. For models
without numerical keypad, enter 6 and 3 in this order using the
The "SELECT 63?" appears on the LCD.
(2) Press the Black Start (Mono Start) key.
The "START 63?" appears on the LCD.
(3) To make the head/carriage unit travel to the center of its travel, press the * key. For models
without numerical keypad, enter * using the
NOTE: In models with touch panel, to display the numerical, * and # keys, it is necessary
to switch the software keypad between the numerical and function keypads by pressing the
Scan and Copy keys simultaneously.
After completion of head replacement or adjustment jobs, press the Stop/Exit key. The
head/carriage unit returns to the home position and then locks itself.
TIP: Holding down the Stop/Exit key for more than five seconds with the scanner cover
opened can also move the head/carriage unit in the same manner as above.
(4) To enable or disable the initial setup mode when the power is applied at the next time,
perform steps (1) and (2) again and then press the 1 or 3 key, respectively. For models
without numerical keypad, enter 1 or 3 using the
If you enable the initial setup mode, wait until the "INIT" appears on the LCD and the
head/carriage unit becomes locked. When the "HEAD LOCKED" appears, turn the power
off.
NOTE: Enabling the initial setup mode resets all counts which can be displayed with
Function code 80 (described in
code 80)
If you disable the initial setup mode, the machine displays the "NOT INIT" on the LCD
and returns to the initial stage of the maintenance mode.
(User-accessible)").
,
and OK keys.
,
Section 9.4.29 "Display of the Equipment's Log (Function
9-42
,
and OK keys.
and OK keys.
Confidential