Brother DCP375CW Service Manual page 486

Injet dcp/mfc
Hide thumbs Also See for DCP375CW:
Table of Contents

Advertisement

Selector
No.
1
Transmission level of DTMF
|
high-band frequency signal
3
4
Transmission level of DTMF
|
low-band frequency signal
6
7
Not used.
8
• Selectors 1 through 6: Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the machine for the Standard.
Never access them.
WSW28
(Function setting 6)
Function
App. 4-33
Setting and Specifications
No. 1 2 3
0 0 0
:
0 dB
0 0 1
: +1 dB
0 1 0
: +2 dB
0 1 1
: +3 dB
1 0 0
:
0 dB
1 0 1
: -1 dB
1 1 0
: -2 dB
1 1 1
: -3 dB
No. 4 5 6
0 0 0
:
0 dB
0 0 1
: +1 dB
0 1 0
: +2 dB
0 1 1
: +3 dB
1 0 0
:
0 dB
1 0 1
: -1 dB
1 1 0
: -2 dB
1 1 1
: -3 dB
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents