Brother DCP375CW Service Manual page 111

Injet dcp/mfc
Hide thumbs Also See for DCP375CW:
Table of Contents

Advertisement

(3.1) Switching pump
The pump switching unit switches the application target of the negative pressure generated by
the pump between the head cap for black ink, the one for color ink, and the air vent cap.
When the purge cam is in a head capping position and the head cap unit fits tightly over the
print head, the pump switching unit is switched to the opening tube to the atmospheric air so
that the pressure in the head caps and air vent cap returns to the normal atmospheric pressure.
Head cap for color ink
Color drain tube
(3.2) Draining ink
The tube pump consists of a pump gear and tube roller. As the pump gear rotates, the tube roller
on its circumference squeezes the main drain tube looped around the pump gear, forcing its
content toward the ink absorber box and creating negative pressure.
Main drain tube
For details about the power transmission route to the head maintenance mechanism, see [ 4 ]
below.
Print head
Head cap for black ink
Black drain tube
To ink absorber box
Pump gear
Tube roller
3-26
To opening to atmospheric air
To ink absorber box
Main drain tube
Pump switching unit
(Purge_3_2_E)
To opening to
atmospheric air
Tube pump
(TubePump)