The TRITON Extreme can receive the following three RPN
messages (tuning, transpose, and pitch bend range).
Tuning
RPN fine tune [Bn, 65, 00, 64, 01]
This RPN message can be used to adjust the detuning for a
program or timbre (in Combination mode), or for a track (in
Sequencer or Song Play modes).
The procedure is as follows.
1 [Bn, 65, 00, 64, 01]: Select RPN parameter 01.
2 [Bn, 06, mm, 26, vv]: Use data entry to set the value. A
value of 8192 [mm, vv=40, 00] is center, 0 [mm, vv=00, 00]
is –100 cents, and 16383 [mm, vv=7F, 7F] is +99 cents.
You can use the universal exclusive Fine Tune message
to adjust the overall tuning that corresponds to the
"Master Tune" (Global P0: 0–1a) parameter. ("About
system exclusive messages" ☞p.295)
Transposing
RPN coarse tune [Bn, 65, 00, 64, 02]
This RPN message can be used to adjust the transposition
for a program or timbre (in Combination mode), or for a
track (in Sequencer or Song Play modes).
The procedure is as follows.
1 [Bn, 65, 00, 64, 02]: Select RPN parameter 02.
2 [Bn, 06, mm, 26, vv]: Use data entry to set the value. Nor-
mally only the upper byte is used.
A value of 8192 [mm, vv=40, 00] is center, 6656 [mm, vv=34,
00] is –12 semitones, and 9728 [mm, vv=4C, 00] is +12 semi-
tones.
You can use the universal exclusive Coarse Tune mes-
sage to adjust the overall tuning that corresponds to the
"Transpose" (Global P0: 0–1a) parameter. ("About sys-
tem exclusive messages" ☞p.295)
Changing the pitch bend range
RPN pitch bend range [Bn, 64, 00, 65, 00]
This RPN message can be used to adjust the pitch bend
range for a program or timbre (in Combination mode) or for
a track (in Sequencer or Song Play modes).
The procedure is as follows.
1 [Bn, 65, 00, 64, 00]: Select RPN parameter 00.
2 [Bn, 06, mm, 26, vv]: Use data entry to set the value. Nor-
mally only the upper byte is used.
A value of 0 [mm, vv=00, 00] is +00, and a value of 1536
[mm, vv=0C, 00] is +12 (one octave). Although it is possible
to set a negative value for a timbre/track, only positive val-
ues can be set using RPN messages.
Controlling the arpeggiator (NPRN)
Arpeggiator operations can be controlled using NRPN (Non
Registered Parameter Number) messages. NRPN messages
can be freely used in non-compatible ways by different man-
ufacturers and models of instrument.
The procedure for using NRPN messages is the same as for
RPN, but you will use NRPN MSB (CC#99) [Bn, 63, mm]
and NRPN LSB (CC#98) [Bn, 62, rr] messages (n: channel,
mm, rr: upper and lower bytes of the parameter number) to
specify the parameter.
294
NRPN arpeggiator on/off
[Bn, 63, 00, Bn, 62, 02, Bn, 06, mm]
This message will be transmitted when you press the
ARPEGGIATOR [ON/OFF] key. When the switch is turned
ON the data will be mm=127 [7F], and when turned OFF the
data will be mm=0 [00], and the arpeggiator will be turned
on/off accordingly. (This can also be specified as a function
of the ASSIGNABLE SWITCH.)
Similarly, the arpeggiator will be turned on/off when this
message is received. (ON when mm is 64 [40] or greater, and
OFF when 63 [3F] or less.)
NRPN arpeggiator gate control
[Bn, 63, 00, Bn, 62, 0A, Bn, 06, mm]
This message will be transmitted when you operate the
ARPEGGIATOR [GATE] knob, and the arpeggiator gate will
change. When this message is received, the result will be the
same.
NRPN arpeggiator velocity control
[Bn, 63, 00, Bn, 62, 0B, Bn, 06, mm]
This message will be transmitted when you operate the
ARPEGGIATOR [VELOCITY] knob, and the arpeggiator
velocity will change. When this message is received, the
result will be the same.
Controlling Valve Force (NRPN)
You can use MIDI NRPN control change messages to control
the VALVE FORCE [ON/OFF] key and INPUT TRIM,
ULTRA BOOST, TUBE GAIN, and OUTPUT LEVEL param-
eters (knobs).
NRPN Valve Force on/off
[Bn, 63, 00, Bn, 62, 10, Bn, 06, mm]
This message is transmitted when you press the VALVE
FORCE [ON/OFF] key. A value of mm=127 [7F] is transmit-
ted for ON, and mm=0[00] is transmitted for OFF, and Valve
Force will switch on/off accordingly.
Receiving this message will switch Valve Force on/off in the
same way. (ON when 'mm' is 64[40] or higher, and OFF
when 'mm' is 63[3F] or lower.)
NRPN Valve Force INPUT TRIM
[Bn, 63, 00, Bn, 62, 11, Bn, 06, mm]
This message is transmitted when you turn the VALVE
FORCE [INPUT TRIM] knob, and the INPUT TRIM will
change. The same result will occur when this message is
received.
NRPN Valve Force ULTRA BOOST
[Bn, 63, 00, Bn, 62, 12, Bn, 06, mm]
This message is transmitted when you turn the VALVE
FORCE [ULTRA BOOST] knob, and the ULTRA BOOST will
change. The same result will occur when this message is
received.
NRPN Valve Force TUBE GAIN
[Bn, 63, 00, Bn, 62, 13, Bn, 06, mm]
This message is transmitted when you turn the VALVE
FORCE [TUBE GAIN] knob, and the TUBE GAIN will
change. The same result will occur when this message is
received.
NRPN Valve Force OUTPUT LEVEL
[Bn, 63, 00, Bn, 62, 14, Bn, 06, mm]
This message is transmitted when you turn the VALVE
FORCE [OUTPUT LEVEL] knob, and the OUTPUT LEVEL
will change. The same result will occur when this message is
received.