Daikin R-410A Service Manual page 370

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

Disassembly and Maintenance
1.16.7 Removal of Drain Pan
1
Warning
Procedure:
Step
If removing the drain pan:
Carry out pump down,
disconnect the transmission
piping and wiring, and
remove the main unit.
Remove side panels,
3
operation display cover and
front cover according to
their removal procedures.
1
Remove the bottom
panel.
5 5
2
Remove the air discharge
section.
5–130
Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure
ESIEN05-04
Points
The bottom panel is fastened to
the unit installation plate by 3
screws.