Daikin R-410A Service Manual page 308

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

Disassembly and Maintenance
Step
1
3
Install the heat
exchanger mounting
plate.
Insert two thermistors.
4
Then cover the header by
3
anti sweat tube.
5 5
5
Reinstall the lead wire of
thermistor and anti sweat
tube on the original
position by using two
pieces of heat resistance
tie wrap.
5–68
Procedure
Heat exchanger
mounting plate
Anti sweat tube
Anti sweat tube
Set the lead wire with yellow
tape (for heating) upper side
while that with no tape (for
liquid) lower side.
(S2681)
(S2682)
∗ Heat resistance tie wrap
Parts No.:1278921
(Drg No.:4SA90202-1)
(S2673)
Part 5 – Disassembly and Maintenance
ESIEN05-04
Points