Fdq125, 200, 250B - Daikin R-410A Service Manual

Sky-air indoor
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

ESIEN05-04
6.8

FDQ125, 200, 250B

PCB
The illustration below shows the PCB connectors.ì
X31A
X18A
X19A
Connectors
The table below describes the PCB connectors.
Connector
X5A
X10A
X11A
X18A
X19A
X21A
X27A
X31A
X33A
X35A
X40A
X60A
X61A
Part 1 – System Outline
X61A
X33A
X60A
X10A
X35A
Connected to
Description
X1M
Terminal strip for P1/P2
T1R
Transformer secondary side
T1R
Transformer primary side
R2T
Coil thermistor (liquid)
R1T
Air thermistor
K1F
Magnetic contactor of fan motor
X2M
Power supply & communication
A3P
PCB
X1A on KRP1B
Connector for wiring adapter KRP1B
X1A on KRP4
Connector to group control adapter power supply (16VDC) for
optional PCB KRP4
Connector for remote ON/OFF, Forced OFF
X1A on DTA112 Connection for interface adapter
X2A on DTA112 Connection for interface adapter
X11A
X40A
X5A
PCB Layout
1
X27A
X21A
1–115
3
4
5

Hide quick links: