Setting Air Guide Vanes - Rinnai Arriva Operation And Installation Manual

Hide thumbs Also See for Arriva:
Table of Contents

Advertisement

Installation - Setting Air Guide Vanes
The air guide vanes allow the installer to set and adjust the horizontal air flow distribution of
the appliance. These are not to be confused with the horizontal louvres that determine the
direction of vertical air flow, these are fixed and cannot be adjusted.
The air guide vanes can be adjusted by carefully bending the air guide vanes to the left or right
as required with a screwdriver.
DO NOT:
Repeatedly adjust the vanes more than 5 times as this may cause the metal to fracture
and/or break
Attempt to adjust the air flow direction while the appliance is operating or still hot as this
can result in a burn injury
rinnai new Zealand Limited
Arriva Operation and Installation Manual: 10343-E
38
05-10