Appliance Positioning

When positioning the unit, the main points governing location are flueing and warm air
distribution.
this heater must not be installed where curtains or other combustible materials could come
into contact with the appliance. In some cases curtains may need restraining.
the rinnai Arriva has a cool outer casing, it can be installed into an existing
Enclosure
masonry or decorative fireplace.
requirements
A pair of wheels located at the rear of the heater allows it to be slid in
and out of the enclosure for commissioning and maintenance. The heater
must be positioned on a flat level surface that allows free movement of the
appliance.
In a masonry fireplace, use a slurry of sand and cement to level the base as
required.
In a decorative fireplace, when the appliance is elevated from the ground,
construct a base using a board with supporting joists as shown.
In elevated installations the front mounting feet of the appliance will
protrude. These can be re-positioned so they fit within the enclosure by
using the slots that sit behind the front wheels.
Joist
rinnai new Zealand Limited
Left
wheel
MDF (Customwood) board, Minimum 20 mm
Enclosure Dimensions
Width (w)
845 - 860 mm
Height (h)
660 - 665 mm
Depth (d)
380 mm direct flue
475 mm extended flue
All dimensions provided are critical to the
installation of this appliance and must be strictly
adhered to.
Wheel
720
Arriva Operation and Installation Manual: 10343-E
25
Right
Joist
w
h
d