Setting the air guide vanes

The air guide vanes allow the installer to set and adjust the horizontal air flow distribution of the
appliance. These are not to be confused with the horizontal louvres that determine the direction
of the vertical flow—these are fixed and cannot be adjusted.
The air guide vanes can be adjusted by carefully bending to the left or right using a screwdriver.
- Do not adjust the vanes more than five times as this may cause the metal to fracture and/or
break
- Do not attempt to adjust the air flow direction while the appliance is operating or still hot as
this could result in a burn injury
14 | Arriva 752 Installation Guide: 12218-F 06-18
Air guide vanes
Air guide vanes can be adjusted to the left or right