Air hose connection

This step in the installation is critical. If the connections are not secured properly, products
of combustion could disperse into the room being heated.
WARNING
The Linear comes with one end of the flexible air hose already connected to the Linear air inlet.
Attach the other end of the air intake hose to the connection on the flue, either the ASPDFK or the
LSFKIT01.
Connect the flue into the Linear combustion fan exhaust, and secure in place (two screws) with the
flue lock bracket (supplied in the plastic bag with the remote control).
Secure the air intake hose on the flue with the cable tie (supplied in the plastic bag with the remote
control), and ensure the rubber cap is in place on the unused air intake.
Rubber cap placed on
the unused air intake
Flue lock bracket
LSFKIT01
holding the
in place.
This end of the flexible
air hose comes already
connected to the air
inlet.
ASPDFK
Air inlet hose
Flue exhaust
locking bracket
44 | Linear installation guide 13563-H 08-19
LSFKIT01
Flue exhaust
connection
Flue exhaust
connection
Large air inlet
connection
Air intake hose
connected to the
LSFKIT01
and
secured with a cable tie
LSFKIT01
connected
into the Linear
combustion fan
exhaust.
Small air inlet connection
(Rubber cap MUST remain in place)