66

6.14.2 Setting the operating pressure

ATTENTION
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
The operating pressure for the pneumatic unit is 6 bar.
Make sure that the operating pressure is set correctly before
putting the machine into operation.
Figure 47: Setting the operating pressure
1. Pull the turning handle (1) up.
2. Set the operating pressure in such a way that the pressure
indicator (2) indicates 6 bar:
To increase the pressure: Turn the turning handle (1) clockwise.
To reduce the pressure: Turn the turning handle (1)
counterclockwise.
3. Push the turning handle (1) down.
(1) - Rotary handle
(2) - Pressure indicator
1
6
4
8
2
10
2
0
Operating manual H868 Version 00.0 - 07/2013