Checking The Pneumatic System - DURKOPP ADLER H868 Operating Manual

Table of Contents

Advertisement

44
ATTENTION
Risk of environmental damage from oil.
Oil is a pollutant and must not enter the sewage system or
the soil.
Carefully collect waste oil and dispose of the waste oil and
oil-contaminated machine parts in the legally prescribed
manner.

5.15.3 Checking the pneumatic system

Figure 28: Pressure indication in the pressure controller
4
2
0
• Check the pressure at the pressure indicator (1) every day:
• Reference value: 6 bar.
• The pressure must not deviate from the reference
pressure by more than 1 bar.
ATTENTION
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
Check the pressure on a daily basis.
Have the pressure adjusted by qualified specialists in
accordance with the information in the  Service manual if
the pressure deviates from the reference value.
q
6
(1) - Reference value: 6 bar
8
(2) - Pressure indicator
10
w
Operating manual H868 Version 00.0 - 07/2013