64
2. Remove the control.
3. Loosen the adaptor cover screws (3).
4. Connect the supply line:
For additionally mounted sewing lights to the X3
connection (1), for integrated LED sewing lights to the 24V/X5
connection (2).

6.13.3 Connecting the direct drive

To do this, read the Operating manual  DAC basic/classic.
Connecting the direct drive consists of the following work:
• Insert the plugs of all connecting cables in the sockets on the
back of the controller.
• Connect the cable for equipotential bonding.
• Connect the controller to the power supply using the power
cable.

6.14 Pneumatic connection

6.14.1 Fitting the maintenance unit

The pneumatic unit is an additional component that is not part of
the standard delivery package.
ATTENTION
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
The system pressure for the pneumatic unit is 8 – 10 bar.
Make sure that the system pressure is set correctly before
fitting the pneumatic unit.