2.9.

CHOOSING THE PILOT LAG TIME

It is possible to change the setting of your unit such that if the thermostat does not call for heat after 45
minutes, the unit will remain at the lowest heat setting (#1) without shutting down (this is the PILOT ON
mode). The stove will remain at the lowest heat level until the thermostat calls for heat again. It is also
possible that the unit shuts down as soon as the thermostat stops calling for heat. This mode is called "PILOT
OFF". Also you can set the lag time to 30, 45 or 60 minutes. If you prefer that your unit runs following one
of these logics, you need to change the setting to PILOT ON or PILOT OFF. In order to change the pilot lag
time, refer to the operation tree at the beginning of this section.

2.10. CHOOSING THE CONVECTION BLOWER SPEED

When you press the convection blower speed button, a screen appears with a cursor to adjust the fan speed
as desired;

2.11. CHOOSING MANUAL OR THERMOSTATIC MODE

In the manual mode, your stove will run continuously at the feed rate selected until the stove runs out of
pellets.
When set in thermostatic mode, the stove will automatically run at the heat level selected until the set room
temperature is reached. When that occurs, the stove will switch to heat setting #1 (lowest), which is the pilot
mode, until the thermostat calls for heat again. When the thermostat calls for heat again, the stove will
increase its feed rate to match the heat setting selected, refer to the operation tree at the beginning of this
section.
2.12. OPERATING THE STOVE USING A
THERMOSTAT
A thermostat may help you maintain a constant
house temperature automatically. A low voltage
thermostat is required. A fixed wall mount or hand
held model can be used. The control panel can be
set up three ways to operate your stove in
thermostatic mode.

2.12.1. Thermostat Installation

Unplug the stove from the power outlet.
Connect two thermostat wires to the terminal
block located on the lower right side of the back
of the stove. To do so, loosen the two screws
and insert the wires in the terminals. Tighten the
two screws. (See figure 22)
Figure 21
Fan Speed Control
FIGURE 22
Rear view

Advertisement