Specifications; Rating; Inverter Rating - Mitsubishi Electric FR-A701 Instrucion Manual

Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

Rating

7 SPECIFICATIONS

7.1 Rating
7.1.1

Inverter rating

200V class
Type FR-A721-
K
Applicable motor capacity (kW)
Rated capacity (kVA)
*2
Rated current (A)
Overload current rating
*3
Voltage
*4
Regenerative braking torque
Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply capacity (kVA)
Protective structure (JEM 1030)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.
*2
The rated output capacity indicated assumes that the output voltage is 220V.
*3
The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty,
allow time for the inverter and motor to return to or below the temperatures under 100% load.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
However, the pulse voltage value of the inverter output side voltage remains unchanged at about
*5
The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).
*6
FR-DU07:IP40 (except for the PU connector)
174
5.5
7.5
5.5
7.5
*1
9.2
12.6
17.6
24
33
12
17
*5
*6
20
22
11
15
18.5
11
15
18.5
23.3
29
46
61
76
150% 60s, 200% 3s (inverse time characteristics)
surrounding air temperature 50°C
Three-phase 200 to 240V
100% continuous 150% 60s
Three-phase 200 to 220V 50Hz, 200 to 240V 60Hz
170 to 242V 50Hz,170 to 264V 60Hz
±
5%
20
28
34
Open type (IP00)
Forced air cooling
33
35
50
22
30
37
22
30
37
34
44
55
90
115
145
41
52
66
52
69
87
that of the power supply.
2
45
55
45
55
67
82
175
215
80
100
90
120

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents