Download  Print this page

Advertisement

Parameter List
Parameter
Fault code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
Communication
startup mode
340
selection
110
Incre
Initial
Name
ments
Value
1
0
1
0
1
0
1
0
1
0
Range
Description
0
Without fault code output
1
With fault code output
2
Fault code output at fault occurrence only
0
Write is enabled only during a stop
1
Parameter write is disabled.
Parameter write is enabled in any
2
operation mode regardless of operating
status.
0
Both forward and reverse rotations allowed
1
Reverse rotation disallowed
2
Forward rotation disallowed
0
External/PU switchover mode
1
Fixed to PU operation mode
2
Fixed to External operation mode
3
External/PU combined operation mode 1
4
External/PU combined operation mode 2
6
Switchover mode
External operation mode (PU operation
7
interlock)
0
As set in Pr. 79.
Started in the network operation mode.
When the setting is "2", it will resume the
1, 2
pre-instantaneous power failure operation
mode after an instantaneous power failure
occurs.
Started in the network operation mode.
Operation mode can be changed between
PU operation mode and network operation
mode from the operation panel.
10, 12
When the setting is "12", it will resume the
pre-instantaneous power failure operation
mode after an instantaneous power failure
occurs.
All
Para
Param
param
meter
eter
eter
copy
clear
clear
: enabled
× : disabled