Mitsubishi Electric FR-A701 Instrucion Manual page 138

Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

Parameter
Name
Remote output
495
selection
496
Remote output data 1
497
Remote output data 2
503
Maintenance timer
Maintenance timer
504
alarm output set time
505
Refer to Pr. 37.
516 to 519
Refer to Pr. 29.
539
Refer to Pr. 343.
547, 548
Parameter for manufacturer setting. Do not set.
549 to 551
Refer to Pr. 343.
Current average
555
time
Data output mask
556
time
Current average
value monitor signal
557
output reference
current
563, 564
Refer to Pr. 52.
569
Refer to Pr. 80.
571
Refer to Pr. 13.
574
Refer to Pr. 95.
575 to 577
Refer to Pr. 127.
611
Refer to Pr. 57.
665
Refer to Pr. 882.
684
Refer to Pr. 82.
800
Refer to Pr. 81.
802
Refer to Pr. 10.
803
Refer to Pr. 22.
Torque command
804
source selection
Torque command
805
value (RAM)
Torque command
806
value
(RAM,EEPROM)
Incre
Initial
Range
ments
Value
Remote output data
0
clear at powering off
Remote output data
1
held at powering off
1
0
Remote output data
10
clear at powering off
Remote output data
11
held at powering off
1
0
0 to 4095
Output terminal can be switched on and
off.
1
0
0 to 4095
Displays the cumulative energization time
of the inverter in 100h increments.
1
0
0 (1 to 9998)
Reading only
Writing the setting of "0" clears the
cumulative energization time.
Set the time taken until when the
0 to 9998
maintenance timer alarm output signal
1
9999
(Y95) is output.
9999
No function
Set the time taken to average the current
0.1s
1s
0.1 to 1.0s
during start bit output (1s).
Set the time for not obtaining (mask)
0.1s
0s
0.0 to 20.0s
transient state data.
Rated
Set the reference (100%) for outputting the
0.01A
inverter
0 to 500A
signal of the current average value.
current
Torque command by terminal 1 analog
0
input
Torque command by parameter
1
Pr.805 or Pr.806 setting (-400% to 400%)
Torque command by using CC-Link (FR-
1
0
3
A7NC)
4
Digital input from the option (FR-A7AX)
5
Torque command by using CC-Link (FR-
A7NC)
6
Digital setting of the torque command can
600 to
1%
1000%
be made by setting Pr. 805 or Pr. 806.
1400%
(Setting from communication option, etc.
can be made.)
600 to
1%
1000%
In this case, set the speed limit value to an
1400%
appropriate value to prevent overspeed.
Parameter List
Para
meter
copy
Description
No remote output
data held at
resetting
Remote output
data held at
resetting
×
×
×
×
All
Param
param
eter
eter
clear
clear
: enabled
× : disabled
×
×
×
×
×
×
×