Mitsubishi Electric FR-A701 Instrucion Manual page 89

Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

Before operation
Phenomenon
4
Motor speed is unstable.
Motor or machine hunts
5
(vibration/noise is
produced).
Acceleration/deceleration
6
time does not match the
setting.
Machine operation is
7
unstable
Speed fluctuates at low
8
speed.
82
Cause
(1) The speed command varies.
(2) Insufficient torque.
(3) The speed control gains do not
match the machine. (mechanical
resonance)
(1) The speed control gain is high.
(2) The torque control gain is high.
(3) The motor wiring is wrong.
(1) Insufficient torque.
(2) Large load inertia.
(1) The speed control gains do not
match the machine.
(2) Slow response because of
improper acceleration/
deceleration time of the inverter.
(1) Adverse effect of high carrier
frequency.
(2) Low speed control gain.
Countermeasures
(1) -1 Check that a correct speed command comes from
the command device. (Take measures against
noises.)
(1) -2 Decrease Pr. 72 PWM frequency selection.
(1) -3 Increase Pr. 822 Speed setting filter 1. (Refer to chapter 4 of
the instruction manual (applied) )
(2) Increase the torque limit value.
(Refer to torque limit of speed control on schapter 4 of
the instruction manual (applied) )
(3) -1 Perform easy gain tuning. (Refer to page 77 )
(3) -2 Adjust Pr. 820, Pr. 821. (Refer to page 79)
(3) -3 Perform speed feed forward/model adaptive speed
control.
(1) -1 Perform easy gain tuning. (Refer to page 77)
(1) -2 Decrease Pr. 820 and increase Pr. 821.
(1) -3 Perform speed feed foward control and model
adaptive speed control.
(2) Decrease the Pr. 824 value.
(3) Check the wiring
(1) -1 Increase the torque limit value.
(Refer to torque limit of speed control on chapter 4 of
the instruction manual (applied) )
(1) -2 Perform speed feed foward control.
(2) Set the acceleration/deceleration time that meets the
load.
(1) -1 Perform easy gain tuning. (Refer to page 77)
(1) -2 Adjust Pr. 820, Pr. 821. (Refer to page 79)
(1) -3 Perform speed feed foward control and model
adaptive speed control.
(2) Change the acceleration/deceleration time to an
optimum value.
(1) Decrease Pr. 72 PWM frequency selection.
(2) Increase Pr. 820 Speed control P gain 1.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents