Appendix 1 Main differences and compatibilities with the FR-A700 series

Item
200V class ......0.4K to 90K
Model configuration
400V class ......0.4K to 500K
Regenerative braking
5.5/7.5K...........100%torque 2%ED
torque
11K to 55K.....20%torque continuous
Built-in EMC filter
With
Pr. 30 Regenerative function selection, Pr. 70 Special
regenerative brake duty
Changed/cleared
Pr. 872 Input phase loss protection selection
functions
Initial value "0" (without input phase protection)
Protective functions
E.BE
· AC reactor (FR-HAL)
· DC reactor (FR-HEL)
· High-duty brake resistor (FR-ABR)
Stand-alone option
· Power regeneration common converter (FR-CV)
· High power factor converter (FR-HC)
· Power regeneration converter (FR-RC)
Outline dimension
Installation size
FR-A700
Not compatible
FR-A701
200V class ..... 5.5K to 55K
400V class ..... 5.5K to 55K
100% torque/continuous
150% torque 60s
Without
Deleted
The initial value is changed to "1" (with input phase
failure protection)
Deleted
E.4, E.10, E.8, E.15 added
Not available
(AC reactor (FR-HAL) is built-in)
* Note that an AC reactor (FR-HAL) should be used only
when a thyristor load exists in the same power supply
system and protective function E.4 and E.10 activate.