Mitsubishi Electric FR-A701 Instrucion Manual page 193

Hide thumbs Also See for FR-A701:
Table of Contents

Advertisement

Outline dimension drawings
Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type with brake)
Frame Number 112M, 132S, 132M
SF-V5RUF(H)
,
3KB
5KB 7KB
Frame Number 160M, 160L
SF-V5RUF(H)
,
11KB 15KB
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Flange
K
K1
K3
K4
Number
3
FF215 112M
5
3
FF265 132S
7
5
3
FF265 132M
11
7
5
FF300 160M
15
11
7
3
FF300 160L
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3. The size difference of top and bottom of the shaft center height is
4. The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
186
,
Connector (for encoder)
Terminal box for cooling fan
MS3102A20-29P
Suction
1
2
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Main terminal box
For brake (B1, B2)
B1
B2
U
Connector (for encoder)
MS3102A20-29P
Terminal box for cooling fan
LL
Suction
1, 2
Direction of
cooling fan wind
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Main terminal box
For motor (U, V, W)
U
V
W
B1
B2
G1
G2
For brake (B1, B2)
For thermal protector (G1, G2)
Frame
Mass
No.
(kg)
D
KB
KD
KL
KP
58
228
239
27
242
178
83
266
256
27
256
197
88
266
294
27
256
197
151
318
318
56
330
231
167
318
362
56
330
231
0
-0.5
LL
LR
KB
Q
KL
LG
LE
Exhaust
Main
QK
terminal box
Section
A
AA
B
B
W
S
Section BB
Terminal box for cooling fan
For motor (U, V, W)
For thermal protector (G1, G2)
For cooling fan (A, B)
V
W
G1 G2
A
B
C
Earthing
Earthing
(grounding)
(grounding)
terminal (M4)
terminal (M4)
KB
LR
KL
LG
LE
Main
Q
terminal box
1
Exhaust
QK
Section
AA
B
B
A
Terminal box for cooling fan
For cooling fan (A, B, C)
Earthing
A
B
C
Earthing
(grounding)
(grounding)
terminal (M8)
terminal (M4)
Motor
LA
LB
LC
LE
LG
LL
LN
215 180j6 250
4
16
525
4
265 230j6 300
4
20
597
4
265 230j6 300
4
20
635
4
300 250j6 350
5
20
735.5
4
300 250j6 350
5
20
779.5
4
1
LN
LZ
2
A
LN
LZ
A
2
W
S
Section BB
indicates an inserting position of a bolt with hex head holes
for manual opening.
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Shaft End
LZ
LR
Q
QK
S
T
U
14.5
60
60
45
28j6
7
4
14.5
80
80
63
38k6
8
5
14.5
80
80
63
38k6
8
5
18.5
110
110
90
42k6
8
5
18.5
110
110
90
42k6
8
5
(Unit: mm)
Terminal Screw Size
W
U,V,W A,B,(C) B1,B2 G1,G2
8
M6
M4
M4
M4
10
M6
M4
M4
M4
10
M6
M4
M4
M4
12
M8
M4
M4
M4
12
M8
M4
M4
M4