Parameter List
Parameter
22
Torque limit level
Constant power
range torque
803
characteristic
selection
Torque limit input
810
method selection
Set resolution
811
switchover
Torque limit level
812
(regeneration)
Torque limit level
813
(3rd quadrant)
Torque limit level
814
(4th quadrant)
Torque limit level 2
815
Torque limit level
816
during acceleration
Torque limit level
817
during deceleration
OLT level setting
874
24 to 27
Refer to Pr. 4 to Pr. 6.
Multi-speed input
28
compensation
selection
102
Incre
Initial
Name
ments
Value
0.1%
150%
1
0
1
0
1
0
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
9999
0.1%
150%
1
0
Range
Description
This functions as torque limit level under
real sensorless vector control.
0 to 400%
Refer to page 101 for stall prevention
operation level.
Constant output limit (torque current limit
0
and control)
Constant torque limit (torque limit and
1
control)
Internal torque limit
0
Parameter-set torque limit operation is
performed.
External torque limit
1
Torque limit based on the analog input
from terminal 1 and 4.
Running speed
increments
0
1r/min
1
0.1r/min
10
1r/min
11
0.1r/min
Set the torque limit level for forward
0 to 400%
rotation regeneration.
9999
Pr. 22 value is used for limit.
Set the torque limit level for reverse
0 to 400%
rotation driving.
9999
Pr. 22 value is used for limit.
Set the torque limit level for reverse
0 to 400%
rotation regeneration.
9999
Pr. 22 value is used for limit.
When the torque limit selection (TL) signal
0 to 400%
is on, the Pr. 815 value is a torque limit
value regardless of Pr. 810.
9999
Depending on Pr. 22 setting
Set the torque limit value during
0 to 400%
acceleration.
9999
Same torque limit as at constant speed
Set the torque limit value during
0 to 400%
deceleration.
9999
Same torque limit as at constant speed
This function can make an inverter trip if
the torque limit is activated to stall the
0 to 200%
motor. Set the output torque at which an
inverter trip is made in Pr. 874 .
0
Without compensation
1
With compensation
Para
Param
meter
eter
copy
clear
: enabled
× : disabled
Torque limit
increments
0.1% increments
0.01% increments
All
param
eter
clear