7.3.2

Dedicated motor outline dimension drawings

Dedicated motor (SF-V5RU(H)) outline dimension drawings (standard horizontal type)
Frame Number 112M, 132S, 132M
SF-V5RU(H)
,
,
3K
5K
7K
Connector (for encoder)
MS3102A20-29P
A
Suction
Direction of
cooling fan wind
Mark for earthing
(grounding)
Earth (ground) terminal (M5)
Frame Number 160M, 160L, 180M, 180L
SF-V5RU(H)
11K
,
15K
,
18K
Connector (for encoder)
MS3102A20-29P
L
A
B
KA
Exhaust
Suction
With guard
wires
Direction of
cooling fan
wind
Mark for earthing
F
F
(grounding)
N
Earth (ground)
terminal (M8)
Sliding distance
W
4
S
Frame leg viewed
from above
Section AA
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Frame
K
K1
K3
K4
No.
3
112M
5
3
132S
7
5
3
132M
11
7
5
160M
15
11
7
3
160L
18
180M
22
15
11
18
15
5
180L
30
7
200L
37, 45
22, 30
18, 22
37
30
11, 15
225S
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
L
R
B
Q
KL
QK
KA
Exhaust
A
A
40
XB
F
F
N
W
S
Section AA
,
22K
R
KL
110
D
90
A
A
50
XB
E
E
M
For motor (U, V, W)
For cooling fan (A, B, C)
For thermal protector (G1, G2)
Mass
(kg)
A
B
C
D
E
F
H
41
278
135
112
228
95
70
226
52
303
152
132
266
108
70
265
62
322
171
132
266
108
89
265
99
412
198
160
318
127
105
316
113
434
220
160
318
127
127
316
138
438.5 225.5 180
363 139.5 120.5 359
160
200
457.5 242.5 180
363 139.5 139.5 359
238
483.5 267.5 200
406
159 152.5 401
255
320
500
277
225
446
178
143
446
0
-0.5
D
A
E
E
M
Sliding distance
ML
4
Frame leg viewed
from above
Frame Number 200L
SF-V5RU(H)
30K 37K
,
Connector (for encoder)
MS3102A20-29P
L
A
KA
Suction
With guard
wires
Direction of
Mark for earthing
cooling fan
F
(grounding)
wind
Earth (ground)
terminal (M12)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the frame installation foot
as well as the earth terminal in the terminal box.
Motor
I
KA
KG KL(KP)
L
M
ML
N
253
69
93
242
478
230
242
180
288
75
117
256
542
256
268
180
288
94
117
256
580
256
268
218
367
105
115
330
735
310
254
367
127
115
330
779
310
298
410
127
139
352
790
335
285
410
146
139
352
828
335
323
145
487
(546)
909
390
361
145
533
(592)
932
428
342
Outline dimension drawings
For cooling fan (A, B)
For motor (U, V, W)
Thermal protector (G1, G2)
B
U
V
W
G1
G2
Earthing (grounding) terminal (M4)
,
45K
R
B
140
D
110
Exhaust
A
A
70
F
XB
E
E
N
M
Sliding distance
W
S
Frame leg viewed
Section AA
from above
Terminal Screw Size
XB
Q
QK
R
S
T
U
W
U,V,W A,B,(C) G1,G2
70
60
45
200 28j6
7
4
8
M6
89
80
63
239
38k6
8
5
10
M6
89
80
63
258
38k6
8
5
10
M6
108
323
42k6
8
5
12
M8
108
345
42k6
8
5
12
M8
121
351.5 48k6
9
5.5
14
M8
121
370.5 55m6
10
6
16
M8
133
425.5 60m6
M10
149
432 65m6
M10
4
(Unit: mm)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
7