Parameter
Name
864
Torque detection
865
Refer to Pr. 41.
866
Refer to Pr. 55.
867
Refer to Pr. 52.
868
Refer to Pr. 858.
872
Refer to Pr. 251.
873
Speed limit
874
Refer to Pr. 22.
875
Fault definition
877 to 881
Refer to Pr. 828.
Incre
Initial
Range
ments
Value
You can make setting to output a signal if
0.1%
150%
0 to 400%
the motor torque exceeds the
predetermined value.
Frequency is limited at the set frequency +
0.01Hz
20Hz
0 to 120Hz
Pr.873 during vector control.
At occurrence of any fault, output is shut
0
off immediately. At this time, the fault
output also turns on.
At occurrence of external thermal
operation (OHT), electronic thermal relay
function (THM) or PTC thermistor function
1
0
(PTC) fault, the motor is decelerated to a
1
stop.
At occurrence of fault other than OHT,
THM and PTC, trips immediately. Same
operation as when "0" is set is performed
under position control.
Parameter List
Para
meter
copy
Description
All
Param
param
eter
eter
clear
clear
: enabled
× : disabled
4
135

Advertisement

Table of Contents

   Also See for Mitsubishi Electric FR-A701

   Related Manuals for Mitsubishi Electric FR-A701

Comments to this Manuals