4.0 LOCATION – PRESIDENT FREE STANDING
4.1 Wall & Floor Fixing
The President FS can be installed against a wall or in the
room away from walls. The appliance is designed to be fixed
to the floor. The appliance can additionally or alternatively be
fixed to a rear wall. The fixing positions are shown in figure
6. The appliance is approved for installation directly on wood
flooring. If the appliance is installed directly on carpeting,
vinyl tile or other combustible material other than wood
flooring, it must be installed on a metal or wood panel
extending the full width and depth of the appliance.

4.2 Venting configurations

4.2.1 Flat on wall
Requires Valor vent kit #551DVK or other pipe length with
adapter #817VAK and terminal cap.
The location requirements are shown in figure 7.
The horizontal vent run cannot be extended beyond the
dimensions shown in figure 5 by the use of any vent accessory
pipes.
4.2.2
Flat on wall with snorkel termination
(Fig.8)
For use on horizontal vent installations where the outside
ground level is too close to the standard terminal. Adapter
#817VAK, a pipe length and snorkel termination will be
required (See vent options section of this manual).
Figure 6 President FS fixing holes
Figure 7
Figure 8
10 of 50