Valor Portrait 530ILN Installation & Owner's Manual

Dv gas fireplace heater

Advertisement

530ILN/ILP (logs), 530ICN/ICP (coals),
WARNING
!
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4001754-18
©2013, Miles Industries Ltd. All rights reserved.
P
ORTRAIT
DV Gas Fireplace Heater
530IRN/IRP (rocks)
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Miles Industries Ltd.
www.valor replaces.com
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the EN-
GINE ONLY. A front trim kit is REQUIRED to install
the engine as it affects the framing cavity and posi-
tion of the engine. A barrier screen is provided with
the front or trim kit. Refer to the manual supplied
with the front for framing and fi nishing.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
C O N S U M E R

Advertisement

Table of Contents
loading

Summary of Contents for Valor Portrait 530ILN

  • Page 1 ORTRAIT DV Gas Fireplace Heater 530ILN/ILP (logs), 530ICN/ICP (coals), 530IRN/IRP (rocks) Installation & Owner’s Manual WARNING I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2013...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO FOLLOW described in this installation manual. NO OTHER vent these installation instructions may result in possible  re system or components MAY BE USED.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, A physical barrier is strongly •• recommended if there are young Parts of your Valor Fireplace become •• children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window ••...
  • Page 5: Owner’' S Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a quali ed dealer. Each Valor  replace •• READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6 OWNER’S Owner’’ s Information INFORMATION Cleaning To remove the window for cleaning: 1. Unhook the front and barrier WARNING screen. 2. Release the top of the window DO NOT TOUCH THE GLASS WHILE IT IS HOT! DO NOT TOUCH THE GLASS WHILE IT IS HOT! by pulling forward and rotating Let the ...
  • Page 7 OWNER’S Owner’’ s Information INFORMATION 7. If the Hot Glass Warning plate has been removed The appliance area must always be kept clear and from the front lower corner of the window, free from combustible materials, gasoline and other reinstall it by sliding it between the glass and ...
  • Page 8: How To Ensure Your Fireplace Cannot Be Turned On Inadvertently

    OWNER’S Owner’’ s Information INFORMATION Lighting, Operation and Rating Information How to Turn Your Fireplace OFF (including pilot) Familiarize yourself with each of these methods before WARNING operating your  replace. DO NOT ATTEMPT TO TOUCH THE DATA PLATE Handset and Wall Switch: Press and hold the OFF WHILE THE FIREPLACE IS STILL HOT! Let the button for a second (either on the handset or the wall ...
  • Page 9: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that on this system, the settings of time, temperature and the fi rst time, the receiver and the handset must be automatic ON/OFF can only be programmed when synchronized.
  • Page 10 OWNER’S Remote Control Operation INFORMATION •• Press and hold (small  ame) MODES OF OPERATION button to decrease  ame height or •• Brie y pressing the SET button to set the appliance at pilot  ame. changes the mode of operation in ••...
  • Page 11 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” TEMPERA- SETTING THE “DAYTIME” TEMPERATURE TURE Default Settings: (sun), 23ºC / 74ºF Default Settings: (moon), “ ” (OFF) TEMP T E M P •• Brie y press SET button to scroll to ••...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME •• You can program two periods of time between 12:00 •• Brie y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the ••...
  • Page 13: Options

    OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.—— 6:00 a.m.—— 8:00 a.m.—— 10:00 p.m.—— 6:00 a.m.—— Start time Start time End time End time Start time Set temp 40F Set temp 74F Set temp 74F Set temp 40F AUTOMATIC TURN DOWN...
  • Page 14: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING : If you do not follow these instructions exactly A. This appliance has a pilot which must be lighted by hand or by remote control. Follow these instructions exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
  • Page 15: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER State of Massachusetts Carbon Monoxide 3. SIGNAGE. A metal or plastic identi cation plate shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 16 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the  ue gases, but identi...
  • Page 17: Speci Cations

    INSTALLER Approvals and Codes Supply Gas This appliance is certi ed to ANSI Z21.88a––2012/ Heater engine 530ILN/ICN/IRN is used for natural gas CSA 2.33a––2012 American National Standard/CSA installations. Standard for Vented Gas Fireplace Heaters for use in Heater engine 530ILP/ICP/IRP is used for propane gas Canada and USA.
  • Page 18: Dimensions, Clearance And Framing

    QUALIFIED Speci cations INSTALLER Venting options Co-Linear Direct Vent Installations for Free Standing or Recessed Installations (fl exible piping) The 530I engine unit is supplied standard with a rear Converts the appliance outlet collars to accept two direct vent outlet and may be converted to a top direct 3-inch diameter ...
  • Page 19: Horizontal Termination Locations

    QUALIFIED Horizontal Termination Locations INSTALLER •• The vent terminal must be located on an outside or a safety hazard. Local codes or regulations may wall or through the roof. require greater clearances. •• This direct vent appliance is designed to operate ••...
  • Page 20: Horizontal Termination Venting Con Gurations

    Flat on the Wall •• Maximum 26”” horizontal pipe length; •• 817VAK Vent Collar Adapter required if using other 14” (36 cm) max. than Valor’’ s 551DVK pipe with termination; within •• A Terminal Guard such as 845TG is required where combustible wall.
  • Page 21 QUALIFIED Horizontal Termination Venting Con gurations INSTALLER See venting accessories list on pages 40––41 for allowable components. Rear Outlet w/Vertical Rise —Horizontal Termination •• 817VAK Vent Collar Adapter required; •• Maximum 2 x 90° elbows allowed (or equivalent: 2 x 45° elbows = 1 x 90°...
  • Page 22: Horizontal Termination Installations

    •• The 530 heater is supplied with a smooth 4-by-6-5/8-inch co-axial collar intended to accept the Valor 551DVK Vent Termination with pipe attached. All other applications will require an 817VAK Vent Adapter to convert the collar to a twist-lock type collar.
  • Page 23: Vertical Termination Venting Con Gurations

    QUALIFIED Vertical Termination Venting Con gurations INSTALLER See venting accessories list on pages 40––41 for allowable components. Rear Outlet through Roof (Co-axial Pipe) Approved vertical termination cap •• 817VAK Vent Collar Adapter required; •• Maximum two 45° elbows allowed for offsetting; Roof ••...
  • Page 24 QUALIFIED Vertical Termination Venting Con gurations INSTALLER See venting accessories list on pages 40––41 for allowable components. Co-linear Venting into Existing Solid-Fuel Approved co-linear termination or approved Burning Fireplaces and Chimneys co-linear adapter 3” min. and approved 2 x 3” Co-linear adapter may be installed as top or rear bend radius Flashing...
  • Page 25: Vertical Termination Installations

    QUALIFIED Vertical Termination Installations INSTALLER See venting accessories list on pages 40––41 for allowable components. All Co-axial Vent Installations Overhang should not extend beyond •• The 530 heater may be installed using components from vent if within 48” of a variety of manufacturers listed on pages 40––41. Horizontal termination cap overhang...
  • Page 26: Appliance Preparation

    QUALIFIED Vertical Termination Installations INSTALLER See venting accessories list on pages 40––41 for allowable components. Co-linear Vent Installations 1. The size of the  replace cavity required to insert the 530 engine varies with the style of front trim chosen. Refer to the front trim installation manual for required dimensions.
  • Page 27 QUALIFIED Appliance Preparation INSTALLER Conversion to Top Outlet for Solid Direct Vent Co-axial Piping If installing with rear vent outlet, go to next step. 1. Remove the top plate and seal by unscrewing 12 screws. Keep the seal, plate and screws for ...
  • Page 28 Vent Outlet Preparation for Co-axial Installations using Non-Valor Vent Components If installing straight off the back venting with Valor terminal kit 551DVK only, ignore this step: 1. Fit the adapter 817VAK over the appliance vent collars pushing on  rmly.
  • Page 29: Air Restrictors Installation

    QUALIFIED Air Restrictors Installation INSTALLER Attaching Air Restrictors—Appliances with Vertical Vent Rise Only Air Restrictor No restrictors are required for appliances which only have a horizontal vent run. If installing an appliance which has a rear vent outlet connection and no vertical vent pipe rise, ignore this stage.
  • Page 30: Gas Supply Installation

    QUALIFIED Gas Supply Installation INSTALLER •• It’’ s preferable to rough-in the gas line at this point •• When testing for leaks: before proceeding with the  rebox installation. •• Make sure that the appliance is turned off. •• The appliance is supplied for supply gas connection ••...
  • Page 31: Ceramic Walls Installation (Logs And Coals Only)

    QUALIFIED Ceramic Walls Installation (logs and coals only) INSTALLER The 530IL and 530IC engines are provided with a set of 1. Locate the ceramic rear wall in the channel at back reversible walls. One side shows the brick pattern and of the ...
  • Page 32: Ceramic Logs Installation

    QUALIFIED Ceramic Logs Installation INSTALLER 1. Place the base log on the supports in the  rebox 5. Locate the left side log on the ceramic pin on the left and against the support at the  rebox back. hand side of the base log. Rest the narrow nose of 2.
  • Page 33: Ceramic Coals Installation

    QUALIFIED Ceramic Coals Installation INSTALLER 4. The center right coal has letter ““R”” embossed 1. Place the base coal on the supports in the  rebox underneath. Place this coal behind the front right and against the  rebox back. coal.
  • Page 34: Ceramic Rocks Installation

    QUALIFIED Ceramic Rocks Installation INSTALLER The ceramic rock set is packed in three cartons. Unpack each piece carefully to avoid damages. You should have in hand the following items: Carton 4001879 Carton 4002055 Carton 4002054 •• Ceramic platform •• Left and right side ••...
  • Page 35: Ceramic Rocks Installation

    QUALIFIED Ceramic Rocks Installation INSTALLER Rock Other Position in the Top row rear Description markers fi rebox Top far left 1 peg under Top row rear Top left 1 peg under Top row rear Top right 1 peg under Top row rear Top far right 1 peg under Top row rear...
  • Page 36: Window Re Tting And Checking

    QUALIFIED Window Re tting and Checking INSTALLER 1. Place the window centrally against the engine unit and resting on the support at bottom front of the engine. 2. Pull the clamping bars forward and rotate inwards to secure the top of the window. 3.
  • Page 37: Operation Check & Aeration Settings Adjustment

    QUALIFIED Operation Check & Aeration Settings Adjustment INSTALLER Operation Check In a few unusual installations, the  ame picture may Turn the  replace  ame up and down using the be improved by adjusting the aeration. The need for remote control to con...
  • Page 38: Remote Control Handset Wall Holder Installation

    QUALIFIED Remote Control Handset Wall Holder Installation INSTALLER The remote control kit for this  replace comes Packing Contents: Alternative 2 Alternative 3 complete with a wall-mounted holder. This holder is not required in all installations but 1 Wall Bracket A is provided as an optional feature for those 2 Screws B 1 Screw C...
  • Page 39: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Optional Wall Switch Kit 1265WSK Connector Yellow GV60 Wiring Diagram...
  • Page 40: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 530, 534, 535, 650, and MF28 Venting Parts Code / availability by Manufacturer Venting Parts Description Co-axial Kit, 26” long — — — — — — 551DVK Standard Co-axial...
  • Page 41 845TG Notes: All listed above co-axial pipes and  ttings require Valor 817VAK Adapter Kit to  t Valor’’ s smooth collars (Valor adapter 4DSC-V by American Metal Products may also be used). 2) Follow instructions supplied with each manufacturer’’ s components.
  • Page 42: Warranty

    OWNER’S Warranty INFORMATION If you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the fi...
  • Page 43: Replacement Parts

    OWNER’S Replacement Parts INFORMATION Code Description Part no. Code Description Part no. Side wall support (2) 330A898 Ignition cable 4001039 Rear wall support 320B320 Ignition cable sleeve 4002244 Velcro strip 4000022 Receiver G6R-R3AM-ZV (CP) 4001911 Port cover 4000828AH Handset G6R H3T5-ZV (BJ) 4001910 Inner vent collar 340B174...
  • Page 44 OWNER’S Replacement Parts INFORMATION 43a, 43b...
  • Page 45 OWNER’S Replacement Parts INFORMATION For 530ILN/P and ICN/P For 530IRN/P only 64 65 66 67...
  • Page 47: Miles Industries Ltd

    Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a quali ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 48: Miles Industries Ltd

    Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

Table of Contents