10.4 Preparing Wall Plates
The wall plates are not used for 7" hole in non-combustible walls.
1.
Bend the wall shields and screw to the inside of the wall plates with 6 thread cutting
screws per plate. See figure 52.
2.
Bend the inner wall plate tab as shown in figure 53 so that the seam on the terminal
tube will pass clearly through the plate with the wall shield at the top. Place the inner
wall plate over the terminal unit. Slide the appliance towards the wall so that the terminal
enters the wall. Slide the inner wall plate up to the wall. Mark the four holes for the wall
screws. Slide the plate away.
3.
Drill and plug the wall.
4.
Screw the plate to the wall with 4 screws provided.
10.4.1 Installing Appliance to Wall.
1.
Slide the appliance fully up to the wall.
2.
Bend the outer wall plate tab as shown in figure 53. Place the outer wall plate over
the terminal unit. Slide the wall plate up to the wall. Mark the four holes for the wall
screws. Slide the plate away.
3.
Drill and plug the wall.
4.
Screw the plate to the wall with 4 screws provided.
See figure 54.
5.
FS installations - Secure the appliance to the floor or wall if necessary.
10.5 Installations except with Valor #551DVK Terminal –
Installing to wall
Unless the wall is totally non-combustible, fit wall thimbles. Slide the
appliance into its correct position and install as detailed in the
manufacturer's instructions supplied with the pipes. FS installations -
Secure the appliance to the floor or wall if necessary.
Important Installer Notice – Weather Sealing &
Vapor Barriers
It is the installer's responsibility to ensure that vent installations
through exterior walls are caulked and weatherproofed in such a
manner as to:
• Prevent rain water from entering the wall from the weather side
by adequately caulking the outer vent plate to the exterior wall
surface.
• Prevent moisture inside the home from penetrating into the wall
structure by ensuring the inside wall plate is adequately sealed to
the inside vapor barrier.
• Prevent rain water and moisture from entering the walls by
sealing the joints between the outer vent tube and the inner and
outer wall plates.
We recommend the use of a high quality polyurethane sealant.
Valor 551 Terminal
33 of 50
Figure 52
Figure 53
Figure 54
Optional 835 Terminal Guard