Valor 530XAN Installation And Owner's Manual page 12

Direct vent gas fireplace heater
Table of Contents

Advertisement

4.2.6 Corner location, rear vent
connection, vertical rise,
horizontal termination
(Figs 9 & 11)
Can be used with either #551DVK standard vent kit
or another terminal cap and accessories.
Adapter #817VAK, two 90° vent elbows and pipe
lengths will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
All vertical dimensional limits are as section 4.2.3.
4.2.7 Rear vent connection, vertical
vent rise with through the roof
termination (Fig.12)
Adapter #817VAK, one 90° vent elbow, pipe
lengths, a vertical vent terminal and roof flashing
will be required. Various other ceiling or roof items
may be necessary depending on the particular
installation (See venting options section of this
manual).
4.2.8 Rear vent connection, vertical
vent rise with offset and through
the roof termination (Fig.13)
For situations where offset is necessary in
an attic to avoid obstructions or allow useful
space.
Adapter #817VAK, one 90° vent elbow,
two 45° vent elbows, wall straps, a vertical
vent terminal, roof flashing and pipe lengths
will be required. Various other ceiling or
roof items may be necessary depending on
the particular installation (See venting
options section of this manual).
Figure 11
Figure 12
Figure 13
12 of 50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

530xap530xcn530xcp

Table of Contents