18.3 WINDSOR ARCH 539 / 549 FRONTS
18.3.1 539 / 549 Kit Contents
1
Outer Cast Iron Arch
1
Inner Cast Iron Arch infill
1
Hearth Fender, cast iron
2
Side mounting brackets
1
Top baffle, sheet metal
1
Top air deflector, sheet metal
2
Stand-off spacers, sheet metal (539
only)
2
Insulation Blanket (539 only)
1
Pack of screws
18.3.2 539/549 Installation
1. Fit the Top Baffle under the top
panel of the appliance case. Secure
with two thread forming screws. See
figure 94. Fit the top air deflector to
the top baffle using the 2 screws
provided as shown in fig. 94.
2. Mount Stand-off Spacers. The
stand-off spacers are supplied flat
and are left and right handed.
Remove the two screws near each of
the rear top corners of the appliance
and the two screws near the rear top of each side.
Bend the spacers as shown in figure 95.
Screw the spacers to the rear of the appliance using the
screws just removed. See figure 95.
Bend the side wings of the spacers to align the two holes in
each spacer with those in the appliance sides. Secure the
spacers using the screws just removed. See figure 95.
!Warning: Failure to install the stand-off spacers may
result in a fire hazard.
.
Fig 95 , Mount Stand-offs